1550nm Channel OADM, Dual LC, Monitor Port | CWDM-OADM1-1550=

1550nm Channel OADM, Dual LC, Monitor Port | CWDM-OADM1-1550=

0.0/5 rating (0 votes)

Description

1550nm Channel OADM, Dual LC, Monitor Port | CWDM-OADM1-1550=

Product Description

The F-tone Networks’s WDM series comprises a set of CWDM passive modules mechanically compatible with the F-tone Networks’s CWDM chassis (part number CWDM-CHASSIS-2=) and a 1300/1550 nm splitter cable. Compared to the previous 1000BASE-CWDM series of passive filters, this new set of devices sports a greatly reduced insertion loss (up to 50 percent), "power-tap" ports to allow live monitoring and troubleshooting of the CWDM signals, as well as the mixing of 1300-nm CWDM signals on the same fiber infrastructures.
F-tone Networks’s CWDM solution applications:The F-tone Networks’s CWDM solution based on CWDM gigabit interface converters (GBICs) and Small Form-Factor Pluggables (SFPs) and passive modules allows enterprise companies and service providers to provide scalable and easy-to-deploy Gigabit Ethernet and Fibre Channel services in their networks. The product set helps enable the flexible design of highly available and scalable multiservice networks.
The F-tone Networks’s CWDM GBIC SFP solution is a convenient and cost-effective solution for the adoption of Gigabit Ethernet and Fibre Channel in campus, data-center, and metropolitan-area access networks.
Because of the flexibility of the passive devices, F-tone Networks’s CWDM solution helps enable the deployment of a variety of topologies to multiplex up to eight different wavelengths on the same pair of fibers in protected or unprotected configurations. A connection between two endpoints is protected when it is associated with two channels (typically of the same wavelength) traveling on diverse fiber routes (for example, clockwise and counterclockwise in ring configurations or on separate fibers in point-to-point scenarios). Single-wavelength OADMs are equipped with two channels traveling different network paths (east and west) to offer redundancy or protection in rings. On the other hand, because CWDM-MUX8A= and CWDM-OADM4-x= have only a single network port (that is, one fiber path), two CWDM-MUX8A= or two CWDM-MUX4-x= are required to connect to redundant (protected) fiber routes.
The following conventions are adopted in the figures:
• Colored circles represent transceivers (GBIC or SFP) at the corresponding color-coded wavelength connected to the filter equipment port.
• N indicates the network port on the CWDM-MUX8A= and CWDM-OADM4-x=.
• P indicates the pass port on the part number CWDM-OADM4-x=.
• E and W indicate the network east and network west ports on the WDM-OADM1-xxxx=.

Specification

Parameters

Unit

CWDM Module

Wavelength Range

nm

1260 ~ 1620

Channel Center Wavelength

nm

1270 / 1290 / … / 1610 or 1271 / 1291 / … /1611

Channel Spacing

nm

20

Channel Passband

nm

λc ± 7.5

Channel No.

λ

2

4

8

16

18

Insertion Loss

dB

≤0.8

≤1.5

≤2.5

≤5.2

≤6.4

Adjacent Channel Isolation

dB

≥ 30

Non-adjacent Channel Isolation

dB

≥ 40

Wavelength thermal stability

nm/¡æ

≤ 0.003

Insertion loss thermal stability

dB/¡æ

≤ 0.005

≤ 0.007

≤ 0.008

PDL

dB

≤ 0.1

≤0.15

≤ 0.15

≤ 0.20

≤ 0.25

Polarization mode dispersion

ps

≤ 0.1

≤ 0.15

Directivity

dB

≥ 50

Return loss

dB

≥ 45

Optical Power

mW

≤ 500

Operating Temperature

¡æ

-10 ~ +70

Storage Temperature

¡æ

-40 ~ +85

Relative Humidity

%

5 ~ 95

Dimension

ABS Box or LGX Box or 1U(2U) Rackmount

· Note: 1. Customization is available.
2. We can make low insertion loss solution as well. For more information, please feel free to contact at ¸ÃÓʼþµØµãÒÑÊܵ½·´À¬»øÓʼþ²å¼þ±£»¤¡£ÒªÏÔʾËüÐèÒªÔÚä¯ÀÀÆ÷ÖÐÆôÓà JavaScript¡£


3. Specified without connector, and add an additional 0.2dB loss per connector.

 CWDM MUX/ DEMUXES SERIES

F-tone Networks can provide more options and customized CWDM,DWDM,MUX,DEMUX series products.

If you have any inquiries,pls feel free to contact us at ¸ÃÓʼþµØµãÒÑÊܵ½·´À¬»øÓʼþ²å¼þ±£»¤¡£ÒªÏÔʾËüÐèÒªÔÚä¯ÀÀÆ÷ÖÐÆôÓà JavaScript¡£

 

CWDM Mux/Demux Without Monitor

Description 

18 Channel CWDM Mux/Demux, 1270~1610nm, IL=4.0dB, LC

16 Channel CWDM Mux/Demux, 1270~1350nm,1410~1610nm, IL=3.5dB, LC

16 Channel CWDM Mux/Demux, Customized, IL=3.5dB, LC

8 Channel CWDM Mux/Demux , 1470~1610nm, IL=2.5dB, LC

8 Channel CWDM Mux/Demux , 1270~1430nm, IL=2.5dB, LC

8 Channel CWDM Mux/Demux , 1270~1350nm,1410~1450nm, IL=2.5dB, LC

8 Channel CWDM Mux/Demux , 1270~1410nm, IL=2.5dB, LC

8 Channel CWDM Mux/Demux , Customized, IL=2.5dB, LC

4 Channel CWDM Mux/Demux , 1470~1530nm, IL=1.5dB, LC

4 Channel CWDM Mux/Demux , 1510~1570nm, IL=1.5dB, LC

4 Channel CWDM Mux/Demux , 1550~1610nm, IL=1.5dB, LC

4 Channel CWDM Mux/Demux , 1270~1330nm, IL=1.5dB, LC

4 Channel CWDM Mux/Demux, 1290~1350nm, IL=1.5dB, LC

4 Channel CWDM Mux/Demux , Customized, IL=1.5dB, LC

2 Channel CWDM Mux/Demux , Customized, IL=1.0dB, LC

 CWDM Mux/Demux w/ Monitor

Description 

18 Channel CWDM Mux/Demux , 1270~1610nm, Monitor Port, IL=4.25dB, LC

16 Channel CWDM Mux/Demux , 1270~1350nm,1410~1610nm, Monitor Port,  IL=3.75dB, LC

16 Channel CWDM Mux/Demux, Customized, Monitor Port, IL=3.75dB, LC

8 Channel CWDM Mux/Demux, 1470~1610nm, Monitor Port, IL=2.75dB, LC

8 Channel CWDM Mux/Demux , 1270~1430nm, Monitor Port, IL=2.75dB, LC

8 Channel CWDM Mux/Demux, 1270~1350nm,1410~1450nm, Monitor Port,  IL=2.75dB, LC

8 Channel CWDM Mux/Demux, 1270~1410nm, Monitor Port, IL=2.75dB, LC

8 Channel CWDM Mux/Demux, Customized, Monitor Port, IL=2.75dB, LC

4 Channel CWDM Mux/Demux , 1470~1530nm, Monitor Port, IL=1.75dB, LC

4 Channel CWDM Mux/Demux, 1510~1570nm,Monitor Port, IL=1.75dB, LC

4 Channel CWDM Mux/Demux , 1550~1610nm, Monitor Port, IL=1.75dB, LC

4 Channel CWDM Mux/Demux , 1270~1330nm, Monitor Port, IL=1.75dB, LC

4 Channel CWDM Mux/Demux , 1290~1350nm, Monitor Port, IL=1.75dB, LC

4 Channel CWDM Mux/Demux , Customized, Monitor Port, IL=1.75dB, LC

2 Channel CWDM Mux/Demux , Customized, Monitor Port, IL=1.25dB, LC

CWDM Mux/Demux w/ Monitor, w/ 1310nm/1550nm

Description 

8 Channel CWDM Mux/Demux, 1470~1610nm, Monitor Port, 1310nm Port, IL=3.0dB, LC

8 Channel CWDM Mux/Demux, 1270~1430nm, Monitor Port, 1550nm Port, IL=3.0dB, LC

8 Channel CWDM Mux/Demux, 1270~1350nm,1410~1450nm, Monitor Port, 1550nm Port, IL=3.0dB, LC

8 Channel CWDM Mux/Demux, 1270~1410nm, Monitor Port, 1550nm Port,  IL=3.0dB, LC

4 Channel CWDM Mux/Demux, 1470~1530nm, Monitor Port, 1310nm Port, IL=2.0dB, LC

4 Channel CWDM Mux/Demux , 1510~1570nm, Monitor Port, 1310nm Port, IL=2.0dB, LC

4 Channel CWDM Mux/Demux, 1550~1610nm, Monitor Port, 1310nm Port, IL=2.0dB, LC

 4 Channel CWDM Mux/Demux, 1270~1330nm, Monitor Port, 1550nm Port, IL=2.0dB, LC

4 Channel CWDM Mux/Demux, 1290~1350nm, Monitor Port, 1550nm Port, IL=2.0dB, LC

 

尊龙凯时人生就是博·(中国游)官网


Figure 2. Point-to-Point Configuration with 4-Channel OADMs and Regeneration

尊龙凯时人生就是博·(中国游)官网


Figure 3. Unprotected Bus Configurations with 4-Channel and 1-Channel OADMs With and Without Regeneration

尊龙凯时人生就是博·(中国游)官网


Figure 4. Protected Hub-and-Spoke Configuration with 8-Channel Multiplexer/Demultiplexer and 4-Channel OADMs

尊龙凯时人生就是博·(中国游)官网


Figure 5. Protected Hub-and-Spoke Configuration with 8-Channel Multiplexer/Demultiplexer and 4-Channel and 1-Channel OADMs

尊龙凯时人生就是博·(中国游)官网


Figure 6. Protected Meshed-Ring Configuration with 4- Channel and 1-Channel OADMs

尊龙凯时人生就是博·(中国游)官网


Figure 7. Protected Meshed-Ring Configuration with 8-Channel Multiplexer/Demultiplexer and 1-Channel OADMs

尊龙凯时人生就是博·(中国游)官网


Figure 8. Mixing 1300-nm and CWDM in Point-to-Point Configuration with 1300-nm OADM Transparency

尊龙凯时人生就是博·(中国游)官网


Figure 9. Mixing 1300-nm and CWDM in Point-to-Point Configuration with WDM Splitter Cable

尊龙凯时人生就是博·(中国游)官网


Figure 10. Mixing 1300-nm and CWDM in Protected Rings with WDM Splitter Cable

尊龙凯时人生就是博·(中国游)官网

Figure 11. WDM Splitter Cable for Non-CWDM Applications

尊龙凯时人生就是博·(中国游)官网

Features and Benefits:The F-tone Networks’s WDM series of CWDM devices offer numerous improvements over the previous generation of devices:
1. Lowest optical insertion loss (refer to Table 2 for details)-Compared to the previous generation of CWDM filters, the insertion loss is reduced up to 50 percent, depending on the model. This translates into much longer distances in both point-to-point and ring configurations.
2. Addition of "monitor" ports on every network port of multiplexers and OADMs as well as on the pass port on OADM4-x to simplify turn-up operations of CWDM networks-The monitor ports also can be used for in-service monitoring of the CWDM signals by means of an optical spectrum analyzer or a power meter.
3. Addition of two 4-channel OADM types for added flexibility: part number CWDM-OADM4-1 to cover the 1470, 1490, 1510, and 1530 channels and part number CWDM-OADM4-2 to cover the 1550, 1570, 1590, and 1610 channels.4. LC/UPC connectors
5. 1300-nm transparency-OADMs are now transparent to "traditional" 1300-nm channels. In other words, the 1300-nm signals can pass through the OADMs with a well-controlled loss. This feature helps enable configurations where CWDM can share the same fiber with traditional SONET/SDH services running on the 1300-nm wavelength.
6. Addition of a WDM splitter (or Y-cable) to multiplexer and demultiplexer channels in the 1300- and 1550-nm ranges-The WDM splitter cable can be used with CWDM optics or with standard 1550 optics. This Y-cable is another tool to integrate on the same fiber infrastructure CWDM with traditional SONET/SDH services running on the 1300-nm wavelength.

Figure 12 Front-Panel Port Configurations of the CWDM-MUX8A, CWDM-OADM4-x, and CWDM-OADM1-xxxx) 

尊龙凯时人生就是博·(中国游)官网


Figure 13. WDM Splitter Cable

尊龙凯时人生就是博·(中国游)官网

 

 

 

 

 

 

 

 

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Search

sitemap¡¢ÍøÕ¾µØͼ