尊龙凯时人生就是博

±ê×¼¹âÄ£¿é

±ê׼ЭÒé¹âÄ£¿é

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

ÊÖÒÕÖ§³Ö

2x2Bypass »úеʽ¹â¿ª¹Ø

2x2Bypass »úеʽ¹â¿ª¹Ø

0.0/5 rating (0 votes)

Description

2x2Bypass »úеʽ¹â¿ª¹Ø

Features

Low Insertion Loss

WideWavelengthRange

Low Crosstalk

High Stability, High Reliability

Epoxy-free on Optical Path

Latching and Non-latching

Applications

R&D in Laboratory

System Monitoring

OADM

MAN (Metropolitan Area Network)

Specifications

Parameters

Unit

FT-D2×2B

Wavelength Range

nm

850±40 / 1300±40

1260~1650

Test Wavelength

nm

850 / 1300

1310/1550

Insertion Loss 1, 2

dB

Typ:1.0   Max:1.5

Return Loss 1, 2

dB

MM ≥ 30  SM ≥ 50

Crosstalk 1

dB

MM ≥ 35  SM ≥ 55

PDL

dB

≤0.05

WDL

dB

≤0.25

         Repeatability

dB

≤±0.02

Operating Voltage

V

3.0  or  5.0

         Durability

Cycles

≥ 10 Million

         Switching Time

ms

≤8

Optical Power

mW

≤500

Operating Temperature

¡æ

-20 ~ +70

Storage Temperature

¡æ

-40 ~ +85

         Relative Humidity

%

5 ~ 95

         Weight

g

14

         Dimension

mm

(L)27.0×(W)12.0×(H)8.2 ±0.2or Customer design

Note: 1 Within operating temperature and SOP.

2Excluding Connectors.

Pin Configurations

Type

State

Optical Route

Electric Drive

Status Sensor

D2×2B

Pin 1

Pin 5

Pin 6

Pin 10

Pin 2-3

Pin 3-4

Pin 7-8

Pin 8-9

Latching

A

P1-P3,P1’-P3’

---

---

GND

V+

Close

Open

Open

Close

B

P1-P4,P2-P3

P1’-P4’,P2’-P3’

V+

GND

---

---

Open

Close

Close

Open

Non-

latching

A

P1-P3,P1’-P3’

---

---

---

---

Close

Open

Open

Close

B

P1-P4,P2-P3

P1’-P4’,P2’-P3’

V+

---

---

GND

Open

Close

Close

Open

DimensionOptical Route尊龙凯时人生就是博·(中国游)官网尊龙凯时人生就是博·(中国游)官网

Electrical Specification

 

Specifications

Voltage

Current

Resistance

5V

latching

4.5~5.5 V

36~44 mA

125 ?

5V

Non-latching

4.5~5.5 V

26~32 mA

175 ?

3V

latching

2.7~3.3 V

54~66 mA

50 ?

3V

Non-latching

2.7~3.3 V

39~47 mA

70 ?

 

 

 

 

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Search

sitemap¡¢ÍøÕ¾µØͼ